Model:FT-SS16S
Brand:tianyi
1.Introduction to Blue-Green Algae Sensor Products
Blue-Green Algae Sensor is a device that uses the principle of fluorescence to monitor the concentration of blue-green algae in real time.Blue-Green Algae Sensor is an electrode-based water quality analysis instrument that uses all-digital electrode detection to detect the blue-green algae parameters of water quality.The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.
2.Blue-Green Algae Sensor host parameters
Charging input voltage | 4.5V-5.5V |
Charging current | <2A |
Screen size | 3.5 inches |
Screen resolution | 480*800☆ |
Screen interface | MIPI DSI☆ |
USB port | 2 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
Type-C | 1 (Support external expansion of mouse, keyboard, 4G, etc.)☆ |
RS485 | 2 (Support Modbus, json, asc input, etc.) |
External sensor power supply voltage | 12V |
External sensor power supply current | 1A |
operating system | ftiot (based on Linux-5.4)☆ |
CPU | 2*Cotex-A7, 650Mhz☆ |
RAM | 512M DDR3☆ |
Flash | 8G-64G |
OpenGL | ES 2.0☆ |
Wifi | support |
4G | Selection |
button | support |
Capacitive touch screen | support |
Software Architecture | B/S☆ |
Web access | Support ☆ |
MTP mode | Support ☆ |
Multi-terminal login | Support ☆ |
IPV6 | Support ☆ |
Sensor communication method | RS485, TCP, UDP, Http☆ |
Data forwarding method | RS485, TCP, UDP, Http☆ |
Remote SSH | Support ☆ |
Remote debugging | Support ☆ |
3.Blue-Green Algae Sensor parameters and configuration
Serial number | name | Measurement range | principle | Measurement accuracy | Resolution | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | 0.01℃ | ||
2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH | 0.01 | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ±6mv | 1mV | ||
4 | Conductivity | 0~5000uS/cm, 0~10000uS/cm | Contact electrode method | ±1.5% | 1uS/cm | ||
5 | TDS | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
6 | salinity | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
7 | Sludge concentration | 0~20.000g/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.001g/L | ||
8 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ±1% | 0.1NTU | Optional | |
0~1000NTU (medium turbidity) | Scattering light method | ±1% | |||||
0~3000NTU (high turbidity) | Scattering light method | ±1% | |||||
9 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ±2% | 0.01mg/L | ||
10 | Ammonia nitrogen | 0~100mg/l | Ion Selection Electrode Method | ±1mg | 0.01mg | ||
11 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.1mg/L | ||
12 | Residual chlorine | 0~5.00mg/L | Ion Selection Electrode Method | ±5% of reading | 0.01mg/L | The best accuracy is when the flow rate is 0.42m/s-0.85m/s | |
13 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | 0.1mg/L | ||
14 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | 0.1mg/L | ||
15 | cod | 0~500mg/L | UV254 absorption method | ±5% | 0.1mg/L | COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window contamination, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | 0.01ug/L | ||
17 | Blue-green algae | 0~200.0Kcells/mL | Fluorescence method | R2>0.999 | 0.1Kcells/mL | ✔ |
As a crucial component of the power system, transmission lines undertake the important task of efficiently transmitting the electrical energy generated by power plants to various regions. By constructing a vast transmission network, electrical energy can travel over long distances to meet the electr...
In today's society, with the acceleration of the processes of industrialization and urbanization, air quality issues have received increasing attention from people. There is a wide variety of pollutants in the air. Among them, the "four gases" (carbon monoxide, sulfur dioxide, nitrogen...
Meteorology and soil moisture are two fundamental elements in agriculture. Meteorology determines the "timing" of agriculture, while soil moisture reflects the "favorable geographical conditions". Together, they form the environmental framework for crop growth.The dynamic changes...
Negative oxygen ion monitoring plays a crucial role in ecological environment research and air quality management. Negative oxygen ions are negatively charged ions in the air, which are widely distributed in the natural environment. Their concentration levels are closely related to air quality. High...