Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-BB1
Brand:tianyi
1.Automatic Brucellosis Detection System system principles and specifications
Automatic Brucellosis Detection System uses fluorescence polarization technology to detect antibodies produced by brucellosis and is designed to detect all Brucella species.
1.The Chinese national standard detection method of the Chinese tiger red plate agglutination test is adopted, combined with the robotic arm to automatically add samples, tiger red antigen, intelligent turbine mixing system, AI image recognition, and special software analysis system.
2.Operation method: fully automatic intelligent detection, no manual sample filling or interpretation is required.
3.Instrument size: 1100mm*750mm*900mm
4.Total instrument volume: approximately equal to 100KG
5.Sample type: serum, milk and other liquids
2.Main performance indicators of Automatic Brucellosis Detection System
1.Test speed: 240 samples per batch, 240 detection speed per hour, and the test time per batch shall not exceed 60 minutes.
2.Support original tube loading: including 1.5ml, 2.0ml centrifuge tube, 5ml syringe, 5ml vacuum blood collection tube.
3.Sample feeding method: double-needle capacitive sample feeding needle, with liquid level detection, no need to replace disposable clinker tip, and save consumable investment.
4.Cleaning method of sample needle: Cleaning special formula cleaning solution (free), carrying contamination rate is less than 5ppm, and the liquid amount can be adjusted by 5-1000ul.
5.Mixing method: The built-in frequency adjustable vortex mixing module can be rotated forward, reverse rotation, and timed mix.
6.Results interpretation: Built-in high-definition microscope working principle, intelligently amplify the sample reaction effect, intelligently judge weak reactions, and avoid false negative samples.
7.Report results: Custom analysis of the software analysis system, sample workload and positive rate, and the results can form graphic reports, Word, Excel, PDF; the test results are permanently preserved, and the results can be traced.
8.Reagent position module: adopts 4 open reagents, and is a general-purpose tiger red antigen reagent sold on the market, and 4 different brands of reagents can be placed at the same time.
9.Sample Reaction Plate: A disposable 12-well flat-bottom plate reaction plate, which can automatically and evenly disperse the detection sample to allow it to react fully and the results are reliable.
10.Lighting system: Built-in top starlight and bottom reactive lighting system.
11.Biosafety: The entire machine is fully enclosed and visual safety cover, built-in ultraviolet disinfection system, can be automatically turned off after regular disinfection, and built-in aerosol adsorption system.
12.Operating system: Chinese control software, which can be remotely upgraded, uploaded to massive cloud storage, automatically saved, etc.
13.Transmission method: Supports WIFI and TCP/IP Gigabit network transmission alone or simultaneously
14.Image acquisition: AI intelligent image acquisition system intelligently collects reaction images within a specified time and uploads them to the control analysis software simultaneously.
3.Automatic Brucellosis Detection System Configuration List
1.Fully automatic intelligent brucellosis detection workstation
2.A set of dedicated control analysis systems
3.Desktop brand controls the entire computer
4.Automatic Brucellosis Detection System After-sales
1.24 months from the date of installation and commissioning.
As a professional monitoring tool specifically designed for the efficient operation of photovoltaic (PV) power plants, the Photovoltaic Weather Station features functional design, parameter selection, and data application that are deeply tailored to the actual needs of PV scenarios. It serves as a c...
Against the backdrop of rapid industrialization, industrial parks—core hubs for industrial agglomeration—face prominent pollution discharge issues. These issues are characterized by complex compositions, diverse types, and high emission intensity. Among them, industrial clusters and parks involvin...
Currently, traditional environmental monitoring methods have some limitations: mainly point-based monitoring with scattered distribution, few online monitoring points, difficulty in accurately tracing pollution sources, and high cost of traditional air automatic monitoring stations. Therefore, the c...
In modern society, with the acceleration of industrialization and urbanization, air outlets in various places, such as factory waste gas discharge ports, garbage treatment plant vents, and sewage treatment plant air outlets, often emit unpleasant odors. These malodorous gases not only seriously affe...