Model:FT-LDTC2
Brand:tianyi
1.Leakage current Measurement substantive requirements (★)
Leakage current Measurement measures leakage current after a disaster occurs and identifies the exact location of the leakage power source.
1.A dual-used Leakage current Measurement, used to determine whether there is a leakage and the specific location of the leakage power after a fire scene, earthquake, typhoon, flood, etc., or after a building collapses, it can alarm soundly and lightly to avoid electric shock accidents.
2.Provide inspection reports issued by national inspection agencies with CNAS or CMA certification marks for the invested products.The inspection and testing agencies that issue the report should obtain qualification certification from relevant national departments and provide the query results of the inspection (test) institutions on the list of "National Qualification Certified Institutions" or "National Quality Inspection Center" certification information public service platform.
3.According to the requirements of the procurement unit, install QR codes and RFID tags that comply with the provisions of the "Fire Fighting Equipment and Materials Internet of Things Identification Management".Before delivery, the equipment must complete the coding work of the local system to ensure that every item is one code.
2.Leakage current Measurement general indicator parameters (●)
1.Used to detect power leakage and confirm the specific location of the leaked power supply.It has the function of automatically detecting electrical strength and weakness.
The wide-angle AC field signal is obtained through the sensor and the program automatically distinguishes high-sensitivity signals from low-sensitivity signals by the program.
and have the ability to adaptively process the induced signal strength.
2.Strap fitting methods: 2 types of strap fitting methods, lanyard type and stainless steel back buckle type
3.The detector can automatically detect the leakage state of the 220V-110KV/50Hz and 120V/60Hz AC power supply, and has the acousto-optical alarm function.When the device is closer to the power supply in the leakage state, the light flashes and the sound frequency of the acousto-optical alarm device is (provided with test report proof materials) ▲
4.Equipped with an OLED LCD screen, the screen size is ≥1.3 inches, which can display power, leakage strength, latitude and longitude information, etc.; (Providing test report proof materials) ▲
5.Alarm sound level intensity: ≥90dB
6.Built-in GPS and Beidou positioning modules, which can obtain their own latitude and longitude position information through the positioning module; (Providing test report proof materials) ▲
7.It has the function of motion static state detection, can detect the state in which it is in a motion state or a static state, and display it on the display screen;
8.It has SOS one-click emergency call and help function, and can realize emergency calls through the SOS physical button on the front of the instrument; (Providing test report proof materials) ▲
9.Built-in LED lighting can be turned on or off through physical buttons on the front of the instrument;
10.LED alarm indicator lights are red and green in 2 colors, 8 LED lights, with lighting grouping function (providing test report proof materials) ▲
11.The detector has a built-in rechargeable battery, and the battery life is ≥10h, which can display the battery status on the display screen.
12.Protection level ≥IP68 (providing test report proof materials)▲
13.Working temperature: -25℃ to 60℃; (Providing test report proof materials)▲
14.Weight (including battery): ≤250g; Size (excluding antenna) ≤140*70*30mm; (Providing test report proof materials) ▲
Against the backdrop of rapid industrialization, industrial parks—core hubs for industrial agglomeration—face prominent pollution discharge issues. These issues are characterized by complex compositions, diverse types, and high emission intensity. Among them, industrial clusters and parks involvin...
Negative oxygen ions are hailed as “air vitamins” and are extremely beneficial to human health. As people’s awareness of health and pursuit of tourism quality have improved, scenic areas’ implementation of negative oxygen ion detection projects can not only create a healthy and comfortable touri...
As a professional monitoring tool specifically designed for the efficient operation of photovoltaic (PV) power plants, the Photovoltaic Weather Station features functional design, parameter selection, and data application that are deeply tailored to the actual needs of PV scenarios. It serves as a c...
instrument used to measure rainfall employs a three-channel narrowband infrared detector and a pure sinusoidal AC signal source, achieving a rainfall resolution of 0.01mm, a rainfall intensity range of 0-4mm/min, and a measurement accuracy of ≤±4%. The device consumes only 0.12W and operates...