Model:FT-SS02
Brand:tianyi
1.Product introduction of Blue Green Algae Test
Blue Green Algae Test uses fluorescence detection to tell you whether the green material you see in the water is likely to be blue-green algae.Blue Green Algae Test is an electrode-based water quality analysis instrument that uses all-digital electrode detection to detect two parameters of water quality chlorophyll and blue-green algae.The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.
2.Blue Green Algae Test host parameters
| Charging input voltage | 4.5V-5.5V | 
| Charging current | <2A | 
| Screen size | 3.5 inches | 
| Screen resolution | 480*800☆ | 
| Screen interface | MIPI DSI☆ | 
| USB port | 2 (Support external expansion of mouse, keyboard, 4G, etc.)☆ | 
| Type-C | 1 (Support external expansion of mouse, keyboard, 4G, etc.)☆ | 
| RS485 | 2 (Support Modbus, json, asc input, etc.) | 
| External sensor power supply voltage | 12V | 
| External sensor power supply current | 1A | 
| operating system | ftiot (based on Linux-5.4)☆ | 
| CPU | 2*Cotex-A7, 650Mhz☆ | 
| RAM | 512M DDR3☆ | 
| Flash | 8G-64G | 
| OpenGL | ES 2.0☆ | 
| Wifi | support | 
| 4G | Selection | 
| button | support | 
| Capacitive touch screen | support | 
| Software Architecture | B/S☆ | 
| Web access | Support ☆ | 
| MTP mode | Support ☆ | 
| Multi-terminal login | Support ☆ | 
| IPV6 | Support ☆ | 
| Sensor communication method | RS485, TCP, UDP, Http☆ | 
| Data forwarding method | RS485, TCP, UDP, Http☆ | 
| Remote SSH | Support ☆ | 
| Remote debugging | Support ☆ | 
3.Blue Green Algae Test sensor parameters and configuration
| Serial number | name | Measurement range | principle | Measurement accuracy | Resolution | Configuration | Remark | 
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | 0.01℃ | ||
| 2 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH | 0.01 | ||
| 3 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ±6mv | 1mV | ||
| 4 | Conductivity | 0~5000uS/cm, 0~10000uS/cm | Contact electrode method | ±1.5% | 1uS/cm | ||
| 5 | TDS | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 6 | salinity | 0-10000ppm 0-200ppt | Contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 7 | Sludge concentration | 0~20.000g/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.001g/L | ||
| 8 | Turbidity | 0~40NTU (low turbidity) | Scattering light method | ±1% | 0.1NTU | Optional | |
| 0~1000NTU (medium turbidity) | Scattering light method | ±1% | |||||
| 0~3000NTU (high turbidity) | Scattering light method | ±1% | |||||
| 9 | Dissolved oxygen | 0~20mg/L | Fluorescence life method | ±2% | 0.01mg/L | ||
| 10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selection Electrode Method | 10% of reading, ±0.5℃ | 0.01mg | ||
| 11 | Suspension | 0~2000mg/L | Scattering light method | ±5% (depending on sludge homogeneity) | 0.1mg/L | ||
| 12 | Residual chlorine | 0~5.00mg/L | Ion Selection Electrode Method | ±5% of reading | 0.01mg/L | The best accuracy is when the flow rate is 0.42m/s-0.85m/s | |
| 13 | Chloride ions | 0-3500.0mg/L | Ion Selection Electrode Method | ±5% | 0.1mg/L | ||
| 14 | Total hardness | 0~1000.0mg/L | Ion Selection Electrode Method | ±10% of reading | 0.1mg/L | ||
| 15 | cod | 0~500mg/L | UV254 absorption method | ±5% | 0.1mg/L | COD, chlorophyll, and blue-green algae are equipped with automatic cleaners, which can prevent biological adhesion and avoid light window pollution, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
| 16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | 0.01ug/L | ✔ | |
| 17 | Blue-green algae | 0~200.0Kcells/mL | Fluorescence method | R2>0.999 | 0.1Kcells/mL | ✔ | 
As a densely - populated public place, the air quality in scenic spots directly affects the tourist experience and ecological value. The negative oxygen ion concentration, as a core indicator for measuring air quality, has made its monitoring system a standard configuration in the construction of sm...
Nowadays, with the rapid development of industry, the pollution problem in industrial parks has attracted much attention. Traditional environmental monitoring methods can no longer meet the needs of refined supervision of pollution in industrial parks. However, the emergence of Air quality monitorin...
The core of the Odor Online Monitor lies in simulating human olfactory perception, enabling simultaneous monitoring of multiple malodorous pollutants. It is particularly suitable for 24/7 continuous monitoring in environments such as landfill sites, chemical industrial parks, and wastewater treatmen...
As a crucial component of the power system, transmission lines undertake the important task of efficiently transmitting the electrical energy generated by power plants to various regions. By constructing a vast transmission network, electrical energy can travel over long distances to meet the electr...