Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-GL02
Brand:tianyi
1.Water Hardness Tester product introduction
Water Hardness Tester is used in pools, spas, hot tubs, faucets and well water to test water quality for total hardness and chloride ions.GL02 Online Water Hardness Tester is an instrument that can monitor the total hardness and chloride ions online.It integrates water hardness sensor, chloride ion sensor and measurement module communication storage, and can quickly and accurately record key parameters in water.At the same time, the instrument supports extended water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data and alarm history records, and support the export of historical data.xlsx.The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2.Water Hardness Tester application field
Online Water Hardness Tester is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1.Factory boiler water quality monitoring: used to prevent scale formation, prevent equipment corrosion, and ensure equipment safety.
2.Groundwater monitoring: used to monitor the pH, conductivity, temperature and other parameters of groundwater in order to promptly discover and solve water quality problems.
3.River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take pollution control measures in a timely manner.
4.Ocean monitoring: used to monitor the ocean's water quality, such as salinity, dissolved oxygen, temperature and other parameters, so as to promptly detect and control marine pollution.
5.Sewage treatment: used to monitor the water quality parameters of sewage, such as pH, COD, ammonia nitrogen, etc., in order to control and regulate the sewage treatment process.
6.Industrial production: used to monitor the water quality conditions in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process process in a timely manner and ensure product quality.
7.Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
8.Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change and other research.
3.Water Hardness Tester technical features
1.High reliability: suitable for long-term working in the wild environment, stable measurement and strong anti-interference ability.
2.Flexible and portable: Each probe can be freely combined, replaced independently, and used for plug and play.
3.Scalability: Freely combine multiple sensors.
4.Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.
5.Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6.Compact structure: can be installed in smaller sizes.
7.Communication connection: RS485 extended interface, master/slave interface isolation can communicate independently.
4.Water Hardness Tester technical parameters
| Display output | 4.3-inch touch screen with LED strong backlight, can be operated under direct sunlight |
| power supply | DC power supply: DC12V |
| Power consumption | The instrument power consumption is about 12V/1W |
| Sound output | buzzer |
| Communication protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
| Main materials | ABS+PC material |
| Storage temperature | -20 to 70℃ |
| Operating temperature | -10 to 50℃ |
| Protection level | IP65 |
| size | 175mm*140mm*49mm(Length×Width×Height) |
| weight | About 0.5KG |
5.Water Hardness Tester sensor configuration
| Model | Name | Measurement range | Principle | Measurement accuracy | Resolution | Is it standard equipment? |
| S2 | Water hardness | 0~1000.0mg/L | Contact method of electrode | Reading ±10%; ±0.3℃ | 0.1mg/L | √ |
| S14 | Chloride ion | 0-3500.0mg/L | Ion selective electrode method | ±5%; ±0.3℃ | 0.1mg/L | √ |
rainfall measuring equipment has a 200mm diameter drum and uses a mechanical tipping bucket combined with electromagnetic induction to collect rainfall data. It has a resolution of 0.2mm, a measurement error of ≤±2%, supports Modbus 485 output, and can monitor rainfall of varying intensities...
In meteorological observation work, the Portable Weather Station has become a commonly used device among practitioners, relying on its three core features: "portability, reliability, and accuracy". Its performance and practicality are widely recognized, enabling it to meet the monitoring n...
COD Analyzer complies with the national standard HJ828-2017 and employs the potassium dichromate oxidation spectrophotometric method. It enhances detection accuracy through dilution injection and chloride ion masking technology. The equipment boasts strong anti-interference capabilities, conve...
Although traditional mechanical wind speed and direction meters have, to some extent, met basic requirements, they have limitations in terms of accuracy, response speed, and reliability. With the advancement of technology, the 3D Ultrasonic Anemometer based on the time - difference method has been d...