Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-SZCY
Brand:tianyi
1. Automatic Water Sampler execution standards:
Automatic Water Sampler collects water samples at predetermined intervals or in response to specific events, such as changes in water level or flow rate.
HJ/T372-2007 "Technical Requirements and Test Methods of Automatic Water Quality Samplers"
HJ 493-2009 "Technology for Preservation and Management of Water Quality Samples"
HJ/91.1-2019 "Technical Specifications for Sewage Monitoring"
HJ/353-2019 "Technical Specifications for Installation of Online Monitoring Systems of Water Pollution Sources (CODcr, NH3-N, etc.)"
2. Automatic Water Sampler application scope:
This product can realize single or continuous mixed collection of sewage at the discharge port, and the mixed samples are used for online analysis equipment to analyze, so as to realize the monitoring function of sewage mixed samples at the discharge port; at the same time, the product has the automatic emptying function of remote sampling bottles.
3. Main features of Automatic Water Sampler:
1. A/B dual bucket configuration: A/B dual bucket configuration can realize continuous mixed sample collection, instrument sampling, sample retention beyond standard and automatic emptying of sampling bottles;
2. Automatic emptying function: Different from the "pipe + electric valve" exhaust method, this product adopts the "automatic turntable + lifting mechanism" exhaust method, which has the advantages of simple pipelines, compact structure, few fault points, and large number of sampling bottles (24 bottles);
3. Remote emptying mode: The remote single bottle and multiple bottle emptying functions can be realized through the monitoring platform;
4. Automatically add preservative agent: It can support the automatic addition of three different preservative agents to ensure the representativeness of the sample;
5. Security function: Supports electronic access control management function, the system automatically generates passwords, records and uploads corresponding information;
6. Real-time network communication interfaces RS232 and RS485 realize remote sampling setting, execution and response functions;
7. The sampling bottle box has a large capacity and the constant temperature is within the range of 4±2℃ all year round;
8. The sampling structure is designed tightly, the pipeline has a backblowing design, and there is no sewage residue to ensure that the sample is pollution-free and authentic;
9. Implement water and electricity separation, completely separate the control part from the mechanical water withdrawal part, so that the instrument is safe and stable;
10. Parallel sample function: The product can realize the parallel sample collection function and provide double samples for enterprises and regulatory units.
11. A manual sampling port with mixed water samples.
12. It has the function of collecting instantaneous water samples.
4. Automatic Water Sampler Technical Indicators
| Main parameters | Parameter range | Main parameters | Parameter range | |||
| Sample quantity | 1~2000mL | Sampling barrel volume | Bucket A: 5L | |||
| Sampling accuracy | Better than ±5% | B barrel: 5L | ||||
| Sample bottle sampling volume | 1~1000mL (customizable) | Bottled | Single, mixed | |||
| Equal proportional sampling error | Better than ±5% | Temperature control error in the chassis | ±2℃ | |||
| Clock control error | Δ1≤0.1 and Δ12≤30s | Horizontal sampling distance | ≥50m | |||
| Vertical head | ≥9m | Sampling time interval | 1~99h59min | |||
| Bottle storage | 1L*24 | Flow measurement range | 0~9999t/h | |||
| Flow input signal | 4~20mA | Operating voltage | (220±15%)V.AC | |||
| Insulation impedance | >50MΩ | MTBF | >3000h | |||
| weight | ≈120kg | External dimensions | 710*620*1520 mm | |||
| Sampling method | Instant sampling, mixed sampling, over-standard sampling, timing sampling, proportional sampling, parallel monitoring sampling | |||||
| Fixing agent type | Dilute sulfuric acid, dilute nitric acid, etc. | Fixing agent consumption | Dilute sulfuric acid: 0~20mL; | |||
| Dilute nitric acid: 0~20mL | ||||||
Negative oxygen ion powder is a special material added to spray paints, mainly composed of natural mineral powders such as tourmaline powder. Tourmaline has pyroelectric and piezoelectric properties: when subjected to temperature or pressure changes, an electric potential difference is generated bet...
The Portable Weather Station is a professional device specifically designed for environmental monitoring. It is not only easy to install and operate with straightforward instructions but also delivers highly accurate measurement data. As a reliable observation system, it can simultaneously monitor m...
Weighing Rain Gauge is based on weighing principle technology, utilizing high-precision sensors to real-time measure the pressure change of precipitation on the receiving container, thereby accurately calculating precipitation intensity. It can measure both liquid and solid precipitation, as well as mixed solid-liquid precipitation, suitable for long-term automatic monitoring needs in hydrology, meteorology, forestry, and other departments....
For a long time, air quality indicators have mostly been negative pollutants such as PM2.5 and sulfur dioxide. In contrast, negative oxygen ions, known as "air vitamins" beneficial to human health, serve as important positive indicators for measuring air freshness and ecological constructi...