Individual Dust Sampler main technical parameters:
Individual Dust Sampler measures workers' exposure to total dust and is an instrument used to measure airborne dust concentrations at work.
1.Sampling flow: Respiratory dust sampling: 2L/min (Flow rate fixed)
2.Sampling flow error: ≤3%FS
3.Sampling flow stability: The sampling flow stability within 8h of the sampler is ≤3.0%FS
4.Load capacity: ≥1000Pa
5.Continuous working hours: ≥8h
6.Working noise: ≤65dB (A)
7.Flowmeter accuracy: not less than level 2.5
8.Sampling time error: ≤0.1% within 5 minutes
9.Average flow rate of the sampling port: 0.5~4.0m/s
10.Airtightness: The sampling head and flowmeter of the sampler are kept for 1 minute under the pressure difference of (1000-1100) Pa, and the pressure change shall not exceed 100Pa.
11.Sampling accuracy error: ≤10%
12.Explosion-proof type: Intrinsically safe mining type ExibI (150℃), suitable for flammable and explosive workplaces and underground sampling of coal mines.
13.Sampling performance: Comply with the "BMRC" sampling efficiency curve;
14.Appearance size: 120×80×42 (mm)
15.Weight: 450g
The Negative Oxygen Ion Monitoring Station features comprehensive multi-factor monitoring capabilities. It can conduct real-time monitoring of multiple environmental factors simultaneously and flexibly add or remove monitoring items according to actual usage needs, so as to adapt to monitoring requi...
Reservoir safety, particularly the flood prevention capacity of the vast number of small and medium-sized reservoirs, is a critical yet vulnerable link in China's flood control and anti-flood system. Facing the current situation of numerous reservoirs built in the last century, which generally s...
TianYi® EL Detector [Model: FT-EL1] Partial Parameters:Detectable Defect Types: Cracks, broken cells, fragments, broken grids, black core, poor soldering, process contamination, low-efficiency cells, black edge, over-firing, over-etching, perforations.Camera: 20-megapixel; Resolution: 4...
In today's society, with the acceleration of the processes of industrialization and urbanization, air quality issues have received increasing attention from people. There is a wide variety of pollutants in the air. Among them, the "four gases" (carbon monoxide, sulfur dioxide, nitrogen...