Tianyi Sensor IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-LS6+
Brand:tianyi
1.Portable open channel flow meter product introduction
Portable open channel flow meter is a compact battery operated Doppler flow meter that provides reliable water flow velocity flow monitoring in open channels.Portable open channel flow meter is a flow velocity flow detection instrument used in rivers, open channels and pipelines.It adopts ultrasonic detection technology, with high measurement accuracy, good stability, less affected by environmental factors, no rotating parts, low maintenance frequency, and high working reliability.It is the first choice for portable flow rate measurement.
Principle: In the field of acoustics, when there is relative movement between the sound source and the receiver (i.e., the probe and the reflector), the frequency of the echo will change.This frequency change is called frequency shift, that is, the Doppler effect.The frequency of the sound wave becomes higher when moving towards the observer and lower when moving away from the observer.Portable open channel flow meter calculates the flow rate by calculating the frequency change.
2.Portable open channel flow meter application field
Scenes such as sponge cities, river chief management, inland river monitoring, natural rivers, open channels, pipelines, and breeding.
3.Main features of Portable open channel flow meter
It can measure pipelines, channels, natural river flow, flow rate, and water level.
The single flow rate sensor is convenient to install and suitable for flow measurements of municipal sewage sewage pipe channels, unsatisfactory pipes, various channels, irregular river channels, natural streams, sewage outlets, etc., and can be installed concealedly, so that long-term and stable work can be achieved.
Instant flow value and cumulative flow value can be provided.
2.8-inch color screen, text and graphics, convenient operation and flow analysis.☆
It can store 10,000 pieces of data and export data through the included USB drive.☆
Low power consumption of sensor: power consumption is <0.8W when measuring flow rate.☆
Chinese and English operating interface, supports one-click switching.☆
Built-in rechargeable lithium battery, standby time exceeds 8 hours.
Built-in pressure water level sensor, temperature sensor.
4.Portable open channel flow meter technical indicators
| parameter | scope | Accuracy | Resolution | 
| Flow rate range | 0.020m/s~6.00m/s☆ | ±1.0%±1mm/s | 1mm/s | 
| Water temperature measurement | -10℃~60℃ | ±0.1 (℃) | 0.1 (℃) | 
| Water depth measurement range | 0.03 meters ~ 10m | 0.3%±0.5cm | 1mm | 
| Instant flow range | 0.001~9999m³/h☆ | ±3% | 0.001m³/s | 
| Cumulative traffic | 0.001~9999m³☆ | ±3% | 0.001m³ | 
5.Portable open channel flow meter performance indicators
| parameter | scope | Remark | 
| Operating voltage | 10.0V~12.6V DC | |
| Battery capacity | 1800mAh☆ | |
| Power consumption of the whole machine | Less than 2.4w | 12V power supply | 
| Working hours | More than 8 hours | |
| Cable length | 20m | |
| Work depth | Less than 10m | |
| Data update cycle | 1 time/second☆ | 
6.Portable open channel flow meter usage requirements
1.The air conductor cable contains a gas pipe and cannot be too bent to prevent it from breaking; do not use the air conductor cable as a cable for the flow meter, and use the air conductor cable to drag the Doppler flow meter;
2.The circular ultrasonic transducer in front of the probe cannot be impacted or scratched;
3.The instrument probe should be avoided for a long time in the sun to avoid failure caused by too high temperature;
4.When using an acoustic Doppler flowmeter in places with high sediment concentration, regularly clean the silt on the ultrasonic transducer and pressure sensor to prevent the silt from blocking the pressure sensor.
Cultural relics carry the memories of human civilization and are precious non-renewable resources. Meteorology, as an important part of the natural environment, has an intricate connection with the protection of cultural relics.Meteorological conditions are directly related to the preservation...
In meteorological observation work, the Portable Weather Station has become a commonly used device among practitioners, relying on its three core features: "portability, reliability, and accuracy". Its performance and practicality are widely recognized, enabling it to meet the monitoring n...
Dust pollution refers to an open-air pollution phenomenon where ground dust is blown into the atmosphere by wind, human activities, or other factors. In ambient air, it is a component of total suspended particles (TSP) and poses a severe threat to atmospheric environmental quality. There are various...
Negative oxygen ion monitoring plays a crucial role in ecological environment research and air quality management. Negative oxygen ions are negatively charged ions in the air, which are widely distributed in the natural environment. Their concentration levels are closely related to air quality. High...